3D reference visualization of the extrusion unit. The approved configuration defines the final machinery, tooling and layout.
خط تولید کابل نرم HK-50 و کابل انشعابی FTTH
متناسب با کابلهایی که قصد تولید آنها را دارید، سفارشیسازی شده است.
Produce simplex / duplex soft cable and FTTH drop cable on a shared HK-50 extrusion platform. Use HK-30-prepared tight-buffered elements for soft cable, or optical fiber and strength members for drop cable. HONGKAI configures the material paths and changeovers around your product mix.
- PRODUCT FAMILIES
- Simplex / duplex soft cable · FTTH drop cable
- SUPPLY APPROACH
- Equipment scope customized for your project
- CONTROL PLATFORM
- Siemens S7 PLC + ADVANTECH IPC
- CONFIGURATION BASIS
- Product drawing, compound and output package
Configure for the actual cable: product changeovers require the appropriate material path, screws, crossheads, guides and operating recipes. Agree the setup and acceptance conditions for each product.
A shared platform with a defined route for each product.
Start with the cable drawing. It determines which incoming materials and equipment are active, how the product passes through the line and what must change between batches.
Prepare the elements for the selected cable.
Feed fiber, buffered elements, aramid and strength members as required. Use the cage-stranding module only when the selected distribution-cable construction calls for it.
Match compound, screw and crosshead.
Dry and feed the selected material, align the incoming elements and use the tooling appropriate to the product profile.
Stabilize the product and check dimensions.
Coordinate warm-water cooling, the fixed trough, chiller, drying, diameter measurement and the specified marking interface.
Control tension through winding.
Choose the traction path, accumulator settings and take-up package. Define the reel-change sequence and finished-product tests.
Soft cable and FTTH. One configurable platform.
The HK-50 platform can be configured for the following indoor and access cable products. Select the families your factory needs; we define the supplied line and changeover arrangements around that mix.
کابل نرم سیمپلکس / دوپلکس
فیبر با روکش فشرده + آرامید + روکش خارجیUse prepared tight-buffered fiber from the HK-30 stage, add the specified aramid reinforcement and extrude a PVC or LSZH outer jacket. Select the tooling for the single- or twin-element profile.
کابل دراپ FTTH
فیبر نوری + اعضای تقویتکننده + روکش پروفایلدارFeed optical fiber and the specified FRP or steel strength members through the drop-cable tooling. A self-supporting variant also needs the approved messenger feed and cable profile.
Starting material: prepared tight-buffered elements for soft cable; supplied optical fiber and the specified strength members for FTTH. HK-30 handles upstream tight buffering. HK-50 forms the finished cable jacket.
Your cable design defines the line.
HK-50 is a custom-configured production line. The two main product routes are reference applications; your technical proposal defines the products, equipment and operating conditions included in your project.
- Products & construction
- Fiber count, cable profile, dimensions and reinforcement.
- Materials & tooling
- Compound grades, screws, crossheads, guides and moulds.
- Process & reel handling
- Tension, cooling, traction, output targets and reel changes.
- Factory integration
- Line direction, space, utilities and control interfaces.
Explore the setup for each product.
Choose a tab to review the material path, relevant equipment and information needed for your configuration.
Soft-cable speed is agreed for the selected construction and compound. The 120 m/min reference applies to 2.0 × 3.0 mm FTTH cable, not every soft-cable product.
Inspect the equipment behind the product routes.
Select a unit to see its job, source parameters and project requirements. The equipment schedule covers the complete reference platform; the active path depends on the chosen product.
3D reference visualization. Final supplied arrangement follows the approved configuration.
24-position cage-stranding module
Combines the specified incoming elements for the distribution-cable extension of the shared platform. It is not required for every simplex, duplex or FTTH route.
- 24-position source configuration
- 25 / 50 km fiber-reel reference
- Online adjustment of rotation and pitch
Required cable construction, actual reel packages, lay and tension; agree whether this module is included.
Selected unit 01: 24-position cage-stranding module
Read each rating with its operating conditions.
These values describe the supplied reference proposal. Product-specific speed, extrusion output, tooling and output reels are confirmed in the technical agreement.
Product & process
| Main product routes | Simplex / duplex soft cable and FTTH drop cable |
|---|---|
| Configured extension | 2–24 core distribution cable; confirm cage-stranding and incoming packages |
| Jacket materials | PVC / LSZH; compound and screw match confirmed per product |
| Extruder reference | 50 mm screw; L/D 25:1 |
| FTTH profile references | 2.0 × 3.0 mm / 2.0 × 5.2 mm |
| FTTH speed reference | 120 m/min for 2.0 × 3.0 mm cable |
| Other product speeds | Agreed for the selected construction, compound and tooling |
| Structural maximum speed | 150 m/min; a separate mechanical rating |
| Take-up reels | PN400–PN630; dimensions and mass confirmed |
| Take-up tension | 5–20 N reference |
Controls & installation
| کنترلها | Siemens S7 PLC + ADVANTECH IPC |
|---|---|
| Approximate line length | 28 m; final layout includes handling and access |
| Approximate installed power | 54 kW source configuration |
| Approximate equipment weight | 5 t source configuration |
| Electrical supply | AC 380 V / 50 Hz / three-phase five-wire reference |
| Compressed air | 0.5–0.6 MPa |
| ارتفاع مرکز ماشین | 1,000 mm |
| Production direction | با خریدار تعیین شده است |
Agree the output by cable construction.
The 120 m/min reference applies to 2.0 × 3.0 mm FTTH cable. Specify the output target for each soft-cable or drop-cable product with its material, tooling, winding and quality checks.
Place HK-50 in the right cable route.
Start with the intended cable. Add upstream preparation and downstream testing according to that construction.
خط تولید بافته شده محکم HK-30
Prepare the buffered fiber elements used in the soft-cable route.
Explore the routeخط تولید کابل قطرهای FTTH
Start with the required indoor or self-supporting cable construction.
Explore the routeخطوط تولید کابل فیبر نوری
Review coloring, loose-tube extrusion, SZ stranding and HK-90 sheathing by process.
Explore the routeVerify both cable setups before acceptance.
Agree the trial products and written test methods for your selected soft-cable and FTTH configurations. Define laboratory equipment separately from the production line.
Use the materials for both product routes.
Prepare the approved buffered elements, optical fiber, aramid and strength members. Record each tooling, tension and recipe change.
Measure the product while it runs.
Confirm dimensions, profile, marking, winding and optical checks for each agreed trial product.
Plan testing as a separate equipment scope.
Select the required mechanical and environmental tests from the cable specification, with suitable fixtures, loads and optical monitoring.
Turn your product mix into a complete factory plan.
Connect product requirements, equipment selection, changeovers and start-up responsibilities in one written technical proposal.
Product & equipment scope
- List every product and required changeover
- Define active equipment and material paths
- Confirm supplied, retained and buyer-supplied items
Factory integration
- Review line layout and handling clearances
- Define utilities, controls and safety interfaces
- محدوده نصب و راهاندازی را توافق کنید
Start-up & support
- Prepare trial materials and acceptance records
- Confirm training and operating documentation
- Agree spare parts and after-sales support
Tell us which products you plan to make.
Start with your cable drawings and the intended product mix. Share the information already available; remaining technical details can be confirmed during review.
Nine inputs for your HK-50 project.
- 01
نقشههای محصول و ترکیب مورد نظر محصول
- 02
Fiber / tight-buffer sizes, counts and reel packages
- 03
PVC / LSZH grades and colors
- 04
Aramid, FRP, steel-wire and messenger requirements
- 05
Required output for each cable product
- 06
Finished reel dimensions, mass and changeover method
- 07
Factory layout, utilities and line direction
- 08
Retained equipment and control interfaces
- 09
Dimensional, optical and mechanical acceptance tests
Questions before specifying a shared soft-cable / FTTH line.
Review product coverage, changeovers, speed ratings and the scope of the HK-50 reference equipment.
01آیا یک خط HK-50 میتواند هم کابل نرم و هم کابل انشعابی FTTH تولید کند؟
بله. پلتفرم اکستروژن مشترک را میتوان برای کابل نرم ساده/دوگانه و کابل انشعابی FTTH پیکربندی کرد. تعویض محصولات مستلزم مواد اولیه مربوطه، مسیر خروجی (pay-off)، راهنماها، هد اصلی (crosshead)/قالبها، تنظیمات کشش، خنککاری و جمعآوری (take-up) است. محدوده تأمینشده و رویه تعویض برای ترکیب محصولات شما توافقشده است.
02نقش خط بافرینگ محکم HK-30 چیست؟
HK-30 a لایه بافر فشرده را روی فیبر نوری پوششدار تأمینشده اعمال میکند. در مسیر کابل نرم، آن عناصر بافرشده آمادهسازیشده سپس وارد دستگاه HK-50 میشوند که تقویتکننده آرامید مشخصشده و روکش بیرونی را اضافه میکند. مسیر FTTH، فیبر نوری تأییدشده و اعضای تحملکننده کشش را به دستگاه اکستروژن کابل انشعابی تغذیه میکند.
03آیا این خط میتواند کابل توزیع را نیز تولید کند؟
پیشنهاد مرجع شامل یک ماژول رشتهگذاری قفسهای 24 موقعیتی و گزینه کابل توزیع هسته 2–24 است. این مسیر را تنها پس از تأیید ساختار کابل، بستهبندی عناصر ورودی، الزامات رشتهگذاری، تقویت، ابزارآلات و دامنه نهایی تجهیزات در نظر بگیرید.
04آیا 120 m/min به هر محصول کابلی اعمال میشود؟
خیر. مرجع منبع 120 m/min برای کابل FTTH با ابعاد 2.0 × 3.0 mm است. سرعتهای کابل نرم، سایر پروفیلهای FTTH و کابل توزیع بر اساس ساختار، ترکیب و کیفیت مورد نیاز توافق میشوند. حداکثر ساختاری 150 m/min یک رتبهبندی مکانیکی جداگانه است.
05آیا تمام واحدهای تجهیزات 16 برای هر محصولی فعال هستند؟
خیر. جدول تجهیزات، پلتفرم مرجع مشترک را توصیف میکند. کابل نرم، FTTH و هر انشعاب کابل توزیع، بستهبندیهای ورودی و مسیرهای مواد فعال متفاوتی را به کار میبرند. پیشنهاد فنی، واحدهای تأمینشده و کاربرد آنها را برای هر محصول انتخابشده مشخص میکند.
06آیا این همانند یک خط کابل لولهشل بیرونی است؟
خیر. این پلتفرم HK-50 برای مسیرهای اکستروژن کابل نرم و FTTH مشخصشده است. یک مسیر رایج بیرونی شامل رنگآمیزی فیبر، اکستروژن لوله شل، بافت SZ در صورت نیاز ساختار کابل و روکش بیرونی HK-90 میشود. انتخاب تجهیزات مطابق نقشه کابل انجام میشود.
07آیا سیستم پیچش دو محوره به معنای تعویض کامل خودکار بوبین است؟
خیر. دو موقعیت کلاف، بازخورد کشش و عرضروی سروو بهتنهایی برش خودکار و انتقال کلاف را فراهم نمیکنند. مراحل اپراتور، استفاده از انباشتگر، روش انتقال و توالی راهاندازی مجدد را در پیشنهاد فنی توافق کنید.
08چه تجهیزات آزمایشی باید همراه با خط برنامهریزی شوند؟
موافقت بر روی بازرسیهای ابعادی و نوری برای تولید و آزمونهای مکانیکی یا محیطی مورد نیاز در مشخصات کابل شما. تجهیزات آزمایشگاهی بهصورت یک حوزه جداگانه برنامهریزی شدهاند که شامل آزمونهای کشش، فشردگی، ضربه، خمش، پیچش یا نفوذ آب میشود، نه اینکه به عنوان بخشی از ایستگاه پیچش یا بستهبندی در نظر گرفته شوند.