Executive Summary
This study investigates how SZ pitch length influences optical attenuation and tube fill uniformity in loose-tube optical cables. Extending pitch length by 10% reduced attenuation by 0.02 dB/km at 1310 nm and improved fill uniformity by 15% across three resin/gel systems. All raw data (CSV) and detailed methods (PDF) are openly available for verification.
Methods
- Equipment: HK-LT-24 line (fw v3.2.1); JDSU MTS-6000 optical tester; XYZ-2000 bend tester.
- Environment: 22 ± 1 °C; 50 ± 5% RH.
- Matrix: Baseline pitch 120 mm vs variant pitch 132 mm (+10%); 3 resin/gel combinations; 10 repeats each.
- Measurements: Attenuation at 1310/1550 nm, ovality (%), fill uniformity (1–5 scale).
- Analysis: Welch’s t-test (α=0.05).
Results
| Pitch | Attenuation (1310 nm, dB/km) | Attenuation (1550 nm, dB/km) | Fill Uniformity (score) |
|---|---|---|---|
| Baseline 120 mm | 0.36 ± 0.02 | 0.22 ± 0.01 | 4.0 ± 0.2 |
| Variant 132 mm | 0.34 ± 0.02 | 0.21 ± 0.01 | 4.6 ± 0.2 |
Extending SZ pitch length improved both attenuation and uniformity.
Downloads
Download CSVDownload Methods PDF
How to Cite
APA
Peter, H. (2025). Loose-Tube SZ Pitch Study v1: Effect of SZ Pitch on Attenuation and Uniformity [Dataset]. Zenodo. https://doi.org/10.5281/zenodo.17052789
BibTeX
@dataset{peter_2025_17052789,
author = {Peter, He},
title = {Loose-Tube SZ Pitch Study v1: Effect of SZ Pitch
on Attenuation and Uniformity
},
month = sep,
year = 2025,
publisher = {Zenodo},
doi = {10.5281/zenodo.17052789},
url = {https://doi.org/10.5281/zenodo.17052789},
} Related Research
- Fiber-Optic Line Cost Model v1 – Transparent cost breakdown (materials, labor, energy, CAPEX) with payback analysis.
- LAN Pair Twisting Benchmark v1 – Double vs triple twist benchmark with throughput and NEXT margins; CSV & methods.