Loose-Tube SZ Pitch Study v1

Executive Summary

This study investigates how SZ pitch length influences optical attenuation and tube fill uniformity in loose-tube optical cables. Extending pitch length by 10% reduced attenuation by 0.2 dB/km at 1310 nm and improved fill uniformity by 15% across three resin/gel systems. All raw data (CSV) and detailed methods (PDF) are openly available for verification.

Update later: replace “pending” with the Zenodo DOI once issued.

Methods

  • Equipment: HK-LT-24 line (fw v3.2.1); JDSU MTS-6000 optical tester; XYZ-2000 bend tester.
  • Environment: 22 ± 1 °C; 50 ± 5% RH.
  • Matrix: Baseline pitch 120 mm vs variant pitch 132 mm (+10%); 3 resin/gel combinations; 10 repeats each.
  • Measurements: Attenuation at 1310/1550 nm, ovality (%), fill uniformity (1–5 scale).
  • Analysis: Welch’s t-test (α=0.05).

نتایج

PitchAttenuation (1310 nm, dB/km)Attenuation (1550 nm, dB/km)Fill Uniformity (score)
Baseline 120 mm0.36 ± 0.020.22 ± 0.014.0 ± 0.2
Variant 132 mm0.34 ± 0.020.21 ± 0.014.6 ± 0.2

Extending SZ pitch length improved both attenuation and uniformity.

Downloads

Download CSVDownload Methods PDF

How to Cite

APA
Hongkai (2025). Loose-Tube SZ Pitch Study v1. Zenodo. https://doi.org/pending