01
SELECTED LAN PROCESS LINE
خط اکستروژن روکش خارجی کابل LAN
روکش خارجی انتخابی را با دامنه تجهیزات مرتبط با هسته کابل، ترکیب، دیواره و بستهبندی نهایی اعمال کنید.
02
PROCESS ROUTE
سیستم روکش را در اطراف هسته ورودی انتخاب کنید
Apply the specified jacket to the assembled LAN cable core. Match the extrusion system, cooling, haul-off, inspection and reel handling to the incoming core, jacket compound and finished cable dimensions.
This stage receives the prepared LAN cable core and applies the specified outer jacket. Review it when adding jacket production, changing a cable construction or replacing a sheathing arrangement. The required wall and finished outside diameter connect the material duty to the extrusion, cooling and haul-off selection. Marking, online inspection and take-up also need a defined scope. A screw diameter or material name alone does not establish the working cable speed or the finished-cable acceptance basis.
Incoming material
هسته کابل پذیرفتهشده و ترکیب روکش تأییدشده
Finished output
کابل LAN روکشدار برای تست و بستهبندی
Select by
جنس روکش، ضخامت دیواره و قطر نهایی
Line scope
از روی نقشه کابل تأییدشده و ورودیهای پروژه تأیید شده است
Turn the assembled core into jacketed cable
Review the relationship between the incoming core and the finished outer jacket. The selected compound, wall thickness, finished diameter and marking requirements drive the sheathing arrangement.
فرآیند تولید را دنبال کنید
STAGE 01
Feed the prepared cable core
Review the core diameter, shielding layers and incoming drum. Set the pay-off and handling arrangement around the actual core construction.
STAGE 02
Extrude the outer jacket
Specify the compound, wall thickness and finished outside diameter. Select screw, crosshead and tooling for that processing duty rather than from a cable-category label alone.
STAGE 03
Cool, inspect and take up
Coordinate cooling, haul-off and take-up with the agreed marking and online checks. Release the finished cable to its specified electrical and packaging operations.
What a well-defined line gives your project
A product-based extrusion duty
Use the jacket section and actual compound to assess the working target. This connects the production requirement to a defined finished cable.
A complete downstream scope
Identify cooling, haul-off, marking, online checks and take-up in the proposal. Each operation can then be reviewed as equipment rather than an assumed accessory.
An acceptance plan for the cable
Separate jacket dimensions and appearance from the finished cable electrical and fire-test requirements. The project can define both without treating the extruder model as a certification.
03
LINE EQUIPMENT
Equipment duties and configuration
Review each module by its function and the project input it needs. Use the documented arrangement as a configuration reference.
Review the line beyond the extruder
Match the core pay-off, extrusion system, cooling path, haul-off and take-up as one route. Add printing and online inspection to the agreed scope where required.
Cable-core pay-off and guiding
Feed the assembled cable core from the specified drum. Review core guides, incoming shield layers and handling through the extrusion entry.
Compound feeding and drying where required
Confirm the actual jacket compound and its material-preparation requirements. Identify any feeding or drying equipment included for the selected processing duty.
اکسترودر اصلی، کنترلهای دما، کراسهد و ابزار
Apply the jacket through the selected crosshead and tooling. Match screw, temperature-control duties and tooling to the compound and jacket section.
Cooling and water-handling arrangement
Define the cooling arrangement and the plant water interfaces. Include the required water-handling responsibility and space in the line layout review.
دندهکشی، شمارش طول و بازرسی آنلاین توافقشده
Coordinate haul-off, length counting and selected online instruments. Agree which inspection functions are provided and how their results are checked.
پشتیبانی پرینتر و جمعکننده کابل نهایی
The listed reference supplies a printer support frame, not the printing machine. Specify any required printer separately. The dual-shaft take-up accepts 400-800 mm reels; confirm its interface to the selected packaging route.
Configuration reference
Documented HK-80 outer-sheath arrangement
- 80 mm screw, L/D 26:1; 30 kW main drive; extrusion output 150 kg/h under open-head conditions. Confirmed reference-line speed: 100 m/min.
- 630-800 mm magnetic-powder pay-off, core guides, 50 kg dryer/loader and PLC line controls.
- 1.5 m movable warm-water trough, 8 m fixed cooling and 600 mm double-wheel capstan.
- Horizontal tension accumulator, spark testing and meter counting; dual-shaft take-up for 400-800 mm reels.
- قاب پشتیبان پرینتر ذکر شده است؛ دستگاه چاپ در آن محدوده مرجع گنجانده نشده است.
Open-head mass output is not finished-cable speed. Confirm jacket compound, wall, cooling and working output in the selected technical proposal.
Choose the configuration route
Compound and tooling selection
Start from the exact jacket compound, core and finished dimensions. Review screw, crosshead, tooling and material preparation for that duty.
Marking and online inspection
Select the printer and inspection functions explicitly. A printing stand, mounting provision or generic control description does not identify the supplied instruments.
Receiving and packaging route
Choose the take-up package to fit the factory handling and the next coiling or delivery operation. Define whether package preparation is a separate stage.
HONGKAI HK-80 control-cable sheathing operating reference. LAN-cable materials, tooling and scope are selected separately.
Watch sheathing equipment in operation
Observe an operating sheathing arrangement and use it to discuss the material path and operator interfaces. This footage shows control-cable equipment; the LAN jacket scope is selected for your construction.
- Incoming-core handling
- Extrusion and downstream line coordination
- Receiving equipment and operator access
04
FACTORY INPUTS
Define the line before comparing quotations
Use the same cable, material and receiving-package requirements when comparing configurations. Unknown items can remain questions for the review.
Your selection brief
Incoming cable core
Provide core diameter, core construction, shield details and incoming drum dimensions.
Jacket specification
Supply the exact compound, required wall thickness, finished diameter, colour and marking requirements.
Acceptance and handling
Define fire-test requirements, online checks, output target, take-up reels and the downstream package format.
Inputs to include
Incoming core
Outside diameter, structure, shielding layers and pay-off drum.
Jacket section
Wall, finished outside diameter, tolerances and colour.
Material specification
Exact compound and its required preparation conditions.
Production duty
Working output for the defined cable and product-changeover expectations.
Marking and inspection
Print content, actual printer and selected online checks.
Receiving and acceptance
Take-up drum, packaging route and cable test requirements.
05
SUPPLY SCOPE & QUALITY
Agree supply scope and acceptance
Put the selected equipment, plant interfaces and product-specific checks into the written proposal.
ACCEPTANCE CHECKPOINTS
Checks to agree
- Agree the jacket dimensional and surface checks for the selected compound.
- Specify the online inspection, marking and length-control equipment to include.
- Confirm finished-cable electrical and fire-test acceptance separately from the extrusion configuration.
SUPPLY BOUNDARY
محدوده برای تأیید
List the marking machine separately from its stand or mounting provision. Confirm the actual printing equipment, cooling utilities, take-up arrangement and testing functions included in the proposal.
Define the acceptance sequence
Trial basis
Agree the representative cable core, exact compound, jacket section and trial tooling.
Line and product checks
Review finished dimensions, surface condition, marking and selected online checks at the agreed operating point.
Records and transfer
Record the take-up and length-control results and identify the separate finished-cable electrical and fire-test acceptance basis.
06
RELATED ROUTES
Connect the upstream and downstream stages
Review the material and receiving packages on both sides of this line, then compare the complete LAN cable route.
Incoming operation
The incoming material is the approved assembled core, including the specified wrapping and shielding layers.
Next operation
Jacketed cable proceeds to its specified release tests and receiving or packaging operation.
Interface to confirm
Review core drum, finished cable drum and packaging interfaces alongside the extrusion and cooling scope.
07
REFERENCE PRICING
Plan your equipment budget
Review the EXW reference price for the named configuration, then request a quotation against your cable drawing, output target and required supply scope.
HK-80 outer-sheathing configuration
USD 53,500
Per reference line
EXW. Taxes excluded.
Confirm your quotation scope
The documented 80 mm outer-jacket extrusion arrangement.
Prices are in USD on an EXW basis and exclude taxes. They apply to the named reference configurations. Final price and validity depend on the agreed equipment, tooling, auxiliaries and project requirements.
Confirm the supply boundary and delivery arrangements in the quotation.
08
CUSTOMER FEEDBACK
Good value, with one project team
Feedback from Devang Shah on HONGKAI’s LAN cable equipment and one-stop project service for Channeltech Systems in India.
Devang Shah
Channeltech Systems
هند
1 customer review
LAN cable equipment project
Equipment value and project support
HONGKAI’s LAN cable production equipment offers good value for money. The service is good, and the one-stop solution saved time for our project.
English summary of customer feedback.
09
QUESTIONS BEFORE SELECTION
Questions before selecting the line
Clarify configuration choices, material duties and process boundaries before turning a reference arrangement into an equipment order.
Mass output and cable line speed are different quantities. The jacket cross-section, compound and complete line arrangement are needed to establish a working production point.
The selected proposal must identify the printer itself. A printing stand or mounting provision is not the same supply item.
Confirm the required classification and finished-cable test basis. The material and process must be assessed within the specified cable construction.
It specifies an 80 mm screw with L/D 26:1 and an open-head extrusion reference of 150 kg/h. The finished cable speed must be confirmed for the compound, jacket section and complete downstream line; it cannot be derived directly from that mass-output figure.
Review the electrical and cooling-water interfaces, material preparation, installation layout and receiving reels. State which equipment and utilities are supplied by each party.
Provide each intended compound and cable section, the product mix and changeover requirements. Confirm the scope and working basis for those products in the technical proposal.
10
PROJECT ENQUIRY
Request a line configuration
خط اکستروژن روکش خارجی کابل LAN
Provide the incoming-core drawing, jacket compound, wall and finished diameter, output target, marking requirements and drum drawings. Identify the required cable tests and downstream package format.
Use the review to agree
- The equipment arrangement and selected configuration route.
- Incoming material, receiving package and plant interfaces.
- The working target, supplied instruments and acceptance basis.
Send the information you already have. Mark undecided requirements for discussion rather than guessing a specification.