लूज़-ट्यूब SZ पिच अध्ययन v1

निष्कर्ष

This study investigates how SZ pitch length influences optical attenuation and tube fill uniformity in loose-tube optical cables. Extending pitch length by 10% reduced attenuation by 0.02 dB/किमी at 1310 nm and improved fill uniformity by 15% across three resin/gel systems. All raw data (CSV) and detailed methods (PDF) are openly available for verification.

विधियाँ

  • उपकरण: HK-LT-24 line (fw v3.2.1); JDSU MTS-6000 optical tester; XYZ-2000 bend tester.
  • Environment: 22 ± 1 °C; 50 ± 5% RH.
  • Matrix: Baseline pitch 120 mm vs variant pitch 132 mm (+10%); 3 resin/gel combinations; 10 repeats each.
  • Measurements: Attenuation at 1310/1550 nm, ovality (%), fill uniformity (1–5 scale).
  • Analysis: Welch’s t-test (α=0.05).

परिणाम

PitchAttenuation (1310 nm, dB/km)Attenuation (1550 nm, dB/km)Fill Uniformity (score)
Baseline 120 mm0.36 ± 0.020.22 ± 0.014.0 ± 0.2
विकल्प 132 mm0.34 ± 0.020.21 ± 0.014.6 ± 0.2

विस्तारित SZ पिच लंबाई ने अपशब्द और समरूपता दोनों को बेहतर बनाया।.

डाउनलोड

डाउनलोड CSVडाउनलोड विधियाँ PDF

कैसे संदर्भित करें

APA
Peter, H. (2025). Loose-Tube SZ Pitch Study v1: Effect of SZ Pitch on Attenuation and Uniformity [Dataset]. Zenodo. https://doi.org/10.5281/zenodo.17052789

BibTeX

@dataset{peter_2025_17052789,
  author       = {Peter, He},
  title        = {Loose-Tube SZ Pitch Study v1: Effect of SZ Pitch
                   on Attenuation and Uniformity
                  },
  month        = sep,
  year         = 2025,
  publisher    = {Zenodo},
  doi          = {10.5281/zenodo.17052789},
  url          = {https://doi.org/10.5281/zenodo.17052789},
}

Zenodo पर डेटासेट देखें