{"id":19127,"date":"2026-11-21T16:56:47","date_gmt":"2026-11-21T08:56:47","guid":{"rendered":"https:\/\/hkcablemachine.com\/?p=19127"},"modified":"2026-11-21T16:56:47","modified_gmt":"2026-11-21T08:56:47","slug":"single-mode-vs-multimode-cable-manufacturing","status":"publish","type":"post","link":"https:\/\/hkcablemachine.com\/fa\/single-mode-vs-multimode-cable-manufacturing\/","title":{"rendered":"\u06a9\u0627\u0628\u0644 \u062a\u06a9\u200c\u062d\u0627\u0644\u062a \u062f\u0631 \u0645\u0642\u0627\u0628\u0644 \u0686\u0646\u062f\u062d\u0627\u0644\u062a: \u0648\u0631\u0648\u062f\u06cc\u200c\u0647\u0627\u060c \u062e\u0637\u0648\u0637 \u0648 \u062a\u0633\u062a\u200c\u0647\u0627"},"content":{"rendered":"<div class=\"product\"><div class=\"product\"><p>Your factory already makes single-mode cable. A customer asks for a multimode version. Do you need a new line to take the order?<\/p>\n<p><strong>Not necessarily. Start with two cross-sections: the cable you make today and the one the customer wants.<\/strong> If both drawings call for the same tight buffer and only the fiber grade changes, check whether the existing payoff can handle the new fiber and its reel. Then agree how to verify the finished cable. If the new drawing calls for fibers inside a loose tube instead, the question changes: which equipment will form that tube, and which parts of the existing line can you keep?<\/p>\n<p>For a quote, send both cable drawings along with the fiber datasheets and reel dimensions. This comparison starts with purchased, coated fiber and ends with cable on a reel. It does not cover drawing the glass or fitting connectors.<\/p>\n<h2>Make Two Product Definitions Before Comparing Machines<\/h2>\n<p>Single-mode fiber is designed to support one guided mode within its specified operating conditions; multimode fiber supports multiple guided modes.<sup id=\"fnref1:1\"><a href=\"#fn:1\" class=\"footnote-ref\" rel=\"footnote\">1<\/a><\/sup> The names describe how light propagates, not how many fibers are inside a cable. A cable containing many individual single-mode fibers is still a single-mode-fiber cable.<\/p>\n<p>For a cable factory buying coated fiber, the optical grade is an input to manufacturing. The factory then makes the specified protective structure around that input. Changing the optical grade does not, on its own, explain whether the next operation is coloring, tight buffering, loose-tube formation, core assembly or sheathing.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/hkcablemachine.com\/wp-content\/uploads\/2026\/11\/01-fiber-and-construction-b3d-v1.jpg\" alt=\"Conceptual coated optical-fiber inputs above separate tight-buffer and loose-tube protection elements.\" title=\"Fiber and construction\"><\/p>\n<p><em>Conceptual 3D illustration, not to scale. Optical-fiber identity and protective construction are separate decisions. The simplified solid-glass and polymer elements are not complete product drawings; their colors do not classify the optical grade.<\/em><\/p>\n<p>Begin the product plan with customer requirements, rather than a prediction that one fiber family will always be more profitable. Ask for the required optical specification, intended system or application, cable drawing, installation conditions and finished delivery form. Single-mode does not mean outdoor by definition, and multimode does not define an indoor cable construction.<\/p>\n<p>Name the exact optical requirement. ITU-T G.652:2024 describes geometrical, mechanical and transmission attributes of a single-mode optical fiber and cable.<sup id=\"fnref1:2\"><a href=\"#fn:2\" class=\"footnote-ref\" rel=\"footnote\">2<\/a><\/sup> ITU-T G.651.1:2018 covers a specified multimode access-network application and distinguishes fiber attributes from delivered-cable attributes.<sup id=\"fnref1:3\"><a href=\"#fn:3\" class=\"footnote-ref\" rel=\"footnote\">3<\/a><\/sup> These references have defined scopes: neither is a complete machine list, and the latter is not a complete specification for every modern multimode category.<\/p>\n<p>Use separate entries for the optical fiber and the cable built around it:<\/p>\n<table>\n<thead>\n<tr>\n<th>Product-definition field<\/th>\n<th>Single-mode candidate<\/th>\n<th>Multimode candidate<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Required optical input<\/td>\n<td>Exact fiber grade, supplier designation and selected specification<\/td>\n<td>Exact fiber grade, required multimode category and supplier designation<\/td>\n<\/tr>\n<tr>\n<td>Purchased input state<\/td>\n<td>Coated fiber, colored fiber or an agreed intermediate<\/td>\n<td>Coated fiber, colored fiber or an agreed intermediate<\/td>\n<\/tr>\n<tr>\n<td>Physical cable drawing<\/td>\n<td>Fiber count, protection, strength members and sheath arrangement<\/td>\n<td>The same fields, completed from its own drawing<\/td>\n<\/tr>\n<tr>\n<td>Manufacturing endpoint<\/td>\n<td>Defined cable or intermediate on a specified reel<\/td>\n<td>Defined cable or intermediate on a specified reel<\/td>\n<\/tr>\n<tr>\n<td>Optical acceptance<\/td>\n<td>Named properties, methods, wavelengths and limits<\/td>\n<td>Named properties, including the applicable bandwidth evidence, methods and limits<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u0627\u0633 \u0633\u0641\u0627\u0631\u0634<\/td>\n<td>Required lengths, product mix and delivery requirements<\/td>\n<td>Required lengths, product mix and delivery requirements<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Do not replace the drawing with a jacket-color choice. A color or sales label may help identify a product within an agreed system, but it is not the complete record of the fiber inside, the cable construction or the acceptance requirements.<\/p>\n<p>The distinction also keeps the project boundary honest. A factory buying coated optical fiber is not buying the equipment that establishes the glass fiber&#39;s optical design. A factory supplying unconnectorized cable is not automatically supplying a tested patch cord. If connectors are part of the order, add the assembly and optical-verification scope explicitly.<\/p>\n<p>For a useful first comparison, choose two products with clearly documented demand. Record which differences are genuinely required by the customer and which are optional proposals. This avoids buying a broad equipment range before the factory knows what it must deliver.<\/p>\n<h2>Inspect the Fiber Package That Will Enter the Line<\/h2>\n<p>The optical description and the machine-handling description belong on the same incoming-material record, but they answer different questions. The optical specification identifies the required fiber. The handling record tells the equipment supplier what will actually pass through the payoff, guides and following operation.<\/p>\n<p>Request the selected supplier&#39;s current data for the supplied coating or colored-fiber diameter and tolerance, coating system, reel dimensions, winding condition and available lengths. Record the actual incoming state: an additional color layer or a purchased buffer must not disappear from the equipment enquiry merely because the order calls the input \u201cfiber.\u201d<\/p>\n<p>Do not size a handling interface from an optical core-size shorthand. The drawing used for a guide or tooling review must identify the physical layer being handled, its diameter and its permissible treatment.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/hkcablemachine.com\/wp-content\/uploads\/2026\/11\/02-incoming-fiber-b3d-v1.jpg\" alt=\"Conceptual solid silica fiber with polymer protection and three incoming-material review fields.\" title=\"Incoming fiber review\"><\/p>\n<p><em>Conceptual 3D illustration. Review the supplied outer layer, package interface and handling guidance using the selected fiber supplier\u2019s data. The enlarged layers and package symbol do not specify dimensions, reel hardware or machine settings.<\/em><\/p>\n<p>The following are review inputs, not universal machine settings:<\/p>\n<ul>\n<li>Fiber supplier, exact designation, batch and matching documentation.<\/li>\n<li>Coating or colored-fiber outside dimensions and the condition entering each process.<\/li>\n<li>Reel flange, barrel, bore, usable width, wound package and attachment interface.<\/li>\n<li>Supplier handling guidance and the proposed tension, guide path and thermal exposure for evaluation.<\/li>\n<li>The identity and dimensions of the intermediate handed to the next operation.<\/li>\n<\/ul>\n<p>Check these fields separately for both products. If a value differs, identify the affected interface; if a value is not supplied, leave the compatibility decision open. A photograph of a reel can support identification, but it should not replace a dimensioned package specification.<\/p>\n<p>For incoming quality, agree which attributes are established by traceable supplier documentation and which need additional verification. Require records that connect the actual fiber lot to the cable lot. Do not describe a supplier&#39;s test report as a test performed by the cable factory, or assume that an incoming report releases the finished cable.<\/p>\n<h2>Separate Shared Hardware from a Qualified Product Range<\/h2>\n<p><strong>A common process function is a reason to investigate reuse, not proof that an existing machine or its saved recipe is qualified for another fiber product.<\/strong><\/p>\n<p>Compare the operation&#39;s input and output before comparing model names. A tight-buffering stage adds the specified close-fitting protection to a fiber input. A loose-tube stage produces the specified tube containing its fiber group. Cable-core formation and final sheathing have their own construction duties.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/hkcablemachine.com\/wp-content\/uploads\/2026\/11\/03-reuse-and-verification-b3d-v1.jpg\" alt=\"Two similar conceptual tight-buffered fiber elements with separate hardware, setup and verification review steps.\" title=\"Reuse and verification\"><\/p>\n<p><em>Conceptual comparison, not to scale. Similar-looking product elements do not demonstrate line compatibility. Review hardware interfaces, record the proposed setup and retain separate verification evidence for each defined product.<\/em><\/p>\n<p>The <a href=\"https:\/\/hkcablemachine.com\/tight-buffered-production-line\/\">HONGKAI HK-30 tight-buffered production reference<\/a> maps fiber payoff and preheating to buffer extrusion, cooling, diameter monitoring, traction and take-up. The <a href=\"https:\/\/hkcablemachine.com\/loose-tube-production-line\/\">\u0645\u0631\u062c\u0639 \u062e\u0637 \u062a\u0648\u0644\u06cc\u062f \u0644\u0648\u0644\u0647 \u0634\u0644<\/a> describes a separate secondary-coating duty and its downstream handoff. These are equipment-route references, not demonstrations that either an unspecified single-mode product or an unspecified multimode product has passed a shared-line trial.<\/p>\n<p>Use a difference-only review to avoid treating every product change as either a complete new line or no change at all:<\/p>\n<table>\n<thead>\n<tr>\n<th>Interface being compared<\/th>\n<th>Information to compare between the two products<\/th>\n<th>Decision the proposal must resolve<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fiber payoff and guide path<\/td>\n<td>Actual input package, fiber condition and proposed handling envelope<\/td>\n<td>Retain, adjust, replace or verify; identify the reason<\/td>\n<\/tr>\n<tr>\n<td>Coloring or buffering, when required<\/td>\n<td>Coating condition, specified applied material and target dimensions<\/td>\n<td>Required process evaluation and product-specific setup record<\/td>\n<\/tr>\n<tr>\n<td>Tube or cable-core formation<\/td>\n<td>Element count, tube arrangement, protection and the next-stage input<\/td>\n<td>Which operations belong in each route; which do not<\/td>\n<\/tr>\n<tr>\n<td>Sheathing and downstream handling<\/td>\n<td>Incoming core, compound, finished dimensions and output package<\/td>\n<td>Tooling, controls and handling scope for each defined construction<\/td>\n<\/tr>\n<tr>\n<td>Inspection and data system<\/td>\n<td>Required properties, test capability and lot identification<\/td>\n<td>Common records versus separate methods, equipment or services<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Three hypothetical order changes show why the distinction matters. They are comparison examples, not HONGKAI project or compatibility records.<\/p>\n<table>\n<thead>\n<tr>\n<th>Proposed product change<\/th>\n<th>What the factory should compare first<\/th>\n<th>What the example does not establish<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>The same tight-buffer construction, but a different approved single-mode or multimode fiber input<\/td>\n<td>Incoming coating and package, handling interfaces, proposed settings and separate optical evidence<\/td>\n<td>That an existing recipe or every installed component is automatically suitable<\/td>\n<\/tr>\n<tr>\n<td>The same optical-fiber grade, but a different tight-buffered, loose-tube or finished-cable construction<\/td>\n<td>Required intermediate, layer arrangement, materials and downstream operations<\/td>\n<td>That keeping the fiber grade keeps the complete production route unchanged<\/td>\n<\/tr>\n<tr>\n<td>The same base cable, but supplied as a connectorized assembly<\/td>\n<td>Connector assembly, end-face work and assembly-specific optical verification<\/td>\n<td>That cable extrusion and a base-cable report complete the assembly order<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For the first comparison, hold the cable drawing, buffer compound and delivery form constant in the review, then identify the actual differences. For the second, mark the changed construction separately from the optical input. For the third, define a new manufacturing endpoint. This keeps additional equipment attached to the duty it must perform, rather than attributing every change to the word \u201csingle-mode\u201d or \u201cmultimode.\u201d<\/p>\n<p>For retained equipment, request an explicit interface decision with its evidence and unresolved work. A proposal should distinguish hardware considered suitable for evaluation, settings still to be established, and product combinations actually demonstrated. No catalogue speed or previous product&#39;s result should silently fill those gaps.<\/p>\n<h2>Keep Attenuation, Bandwidth and Link-Loss Evidence Distinct<\/h2>\n<p>A test plan should identify the object being measured before naming the instrument. Incoming fiber, cabled fiber, a connectorized assembly and an installed link are different objects. Their records may support the same supply chain without being interchangeable acceptance reports.<\/p>\n<p>IEC 60793-1-40:2024 describes attenuation measurement methods, including cut-back, insertion loss and backscattering; its public summary also identifies the point-discontinuity role of backscattering.<sup id=\"fnref1:4\"><a href=\"#fn:4\" class=\"footnote-ref\" rel=\"footnote\">4<\/a><\/sup> IEC 60793-1-41:2024 describes modal-bandwidth measurement methods for multimode optical fiber.<sup id=\"fnref1:5\"><a href=\"#fn:5\" class=\"footnote-ref\" rel=\"footnote\">5<\/a><\/sup> An attenuation or OTDR result therefore should not be relabelled as a modal-bandwidth result.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/hkcablemachine.com\/wp-content\/uploads\/2026\/11\/04-optical-evidence-b3d-v1.jpg\" alt=\"Conceptual evidence map separating attenuation, multimode bandwidth and assembly or link-loss measurements.\" title=\"Optical evidence map\"><\/p>\n<p><em>Conceptual evidence map; no test results are shown. The simplified fiber and cable elements identify measurement objects, not approved cable constructions. The link symbol is not a splice or connector design. Low loss does not establish multimode bandwidth.<\/em><\/p>\n<table>\n<thead>\n<tr>\n<th>Evidence lane<\/th>\n<th>Question the record should answer<\/th>\n<th>Do not substitute<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc \u0648\u0631\u0648\u062f\u06cc<\/td>\n<td>Does this identified lot have the required fiber characteristics and documentation?<\/td>\n<td>A generic supplier brochure or an unrelated lot&#39;s report<\/td>\n<\/tr>\n<tr>\n<td>Finished-cable attenuation<\/td>\n<td>What was measured on this cabled product using the agreed method and conditions?<\/td>\n<td>An incoming-fiber result alone<\/td>\n<\/tr>\n<tr>\n<td>Multimode bandwidth evidence<\/td>\n<td>Which required bandwidth property, method and fiber lot does the evidence cover?<\/td>\n<td>A low-loss trace or a cable appearance check<\/td>\n<\/tr>\n<tr>\n<td>Connectorized assembly or installed link, if in scope<\/td>\n<td>Which loss\/reference method and launch conditions apply to this object?<\/td>\n<td>A base-cable production record<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Agree the measurement wavelengths from the selected product and method, rather than copying one instrument setup across both fiber families. Record the setup, equipment identification, relevant reference conditions, sample or reel, results and applicable acceptance limits. Where results from different stages are compared, document enough conditions to establish that the comparison answers the same question.<\/p>\n<p>Multimode link-loss measurement introduces a further distinction. EXFO&#39;s explanation of encircled flux describes controlled source launch conditions for repeatable multimode link-loss testing.<sup id=\"fnref1:6\"><a href=\"#fn:6\" class=\"footnote-ref\" rel=\"footnote\">6<\/a><\/sup> That is useful when the scope includes the relevant link or assembly measurement. It is not a replacement for multimode fiber-bandwidth evidence and is not, by itself, a universal finished-cable factory test instruction.<\/p>\n<p>The <a href=\"https:\/\/hkcablemachine.com\/what-equipment-is-needed-for-the-fiber-optic-cable-test-lab\/\">fiber-optic factory test-planning guide<\/a> helps separate material, cable, assembly and laboratory requirements. For this comparison, the key purchasing action is to assign each required record to its provider: fiber supplier, cable factory, equipment supplier or an agreed external laboratory. Do not imply that HONGKAI performs or supplies every test simply because a test appears in the plan.<\/p>\n<h2>Choose the First Qualification Product and Price the Remaining Scope<\/h2>\n<p>The first qualification product should follow the actual order specification. There is no useful universal answer that every new factory should start with single-mode or with multimode. Use the following sequence to narrow the decision:<\/p>\n<ul>\n<li><strong>A confirmed order specifies single-mode cable:<\/strong> define the exact fiber grade and cable drawing, then review that product&#39;s route and acceptance evidence. Do not add a multimode range merely because some process modules look similar.<\/li>\n<li><strong>A confirmed order specifies multimode cable:<\/strong> identify the required category and its supporting optical evidence, as well as the physical cable construction. Do not treat a low-attenuation measurement as the missing bandwidth record.<\/li>\n<li><strong>The factory needs both:<\/strong> choose a representative product from each required range and complete the interface comparison for both. Separate shared hardware from changes and verification work still to be priced.<\/li>\n<li><strong>The product requirements are not settled:<\/strong> obtain target specifications, required quantities and sample constructions before fixing the equipment scope. An unanswered product question should remain open rather than becoming an assumed machine capability.<\/li>\n<\/ul>\n<p>For the two candidate products, prepare a qualification worksheet with separate columns. Record the drawing revision and fiber lot, incoming package, retained equipment, proposed changes, trial conditions, required measurements, result-file references and approving parties. Leave result fields empty until work is performed. A planned trial is not a passed trial, and a diagram is not a production record.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/hkcablemachine.com\/wp-content\/uploads\/2026\/11\/05-product-range-b3d-v1.jpg\" alt=\"Two conceptual product folders and protected optical-fiber samples above unfilled qualification record fields.\" title=\"Product range review\"><\/p>\n<p><em>Conceptual planning aid, not an acceptance record. Keep fiber identity, the product drawing, process setup and test evidence separate for each product. The fields remain to be verified; no trial, result or approval is implied.<\/em><\/p>\n<p>Evidence to request: A written explanation of what the equipment offer covers for each named product, which interfaces remain to be verified, and which optical or finished-cable records must come from another party.<\/p>\n<p>Keep the commercial comparison equally specific. Separate base equipment, product-specific tooling, required measuring capability, external testing, operator preparation and any later extension of the range. Obtain current project quotations where costs matter; this guide does not assign generic prices, profit margins, market shares or a payback period to either fiber family.<\/p>\n<p>If the factory plans both products, agree how material identification and setup records remain distinct during order changes. Ask how the demonstrated product range will be recorded and what further evidence will be needed when a fiber supplier, coating system, cable construction or required test changes. One successful product must not become an undefined promise covering every subsequent grade.<\/p>\n<p>The useful purchasing outcome is a bounded product range: one or both named cable products, the equipment and interfaces assessed for them, and the evidence still needed for release. That gives the factory a practical starting point without confusing an optical label with a complete production-line specification.<\/p>\n<div class=\"footnotes\">\n<hr \/>\n<ol>\n<li id=\"fn:1\">\n<p>The Open University, <a href=\"https:\/\/www.open.edu\/openlearn\/digital-computing\/digital-communications\/content-section-2.2\" rel=\"nofollow noopener\" target=\"_blank\">Digital communications \u2014 2.2 Fibre types<\/a>, the university&#39;s original course explanation around Figure 3, checked 19 November 2026. Used only for the qualitative single-mode\/multimode distinction; its historical standard editions, dimensions, application rankings and regional statements are not adopted.&#160;<a href=\"#fnref1:1\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:2\">\n<p>ITU-T, <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.652-202408-I\/en\" rel=\"nofollow noopener\" target=\"_blank\">G.652 (08\/2024) \u2014 Characteristics of a single-mode optical fibre and cable<\/a>, current-edition listing and linked public summary checked 19 November 2026. Used to identify the specification&#39;s scope, not to adopt a universal cable design or operating limit.&#160;<a href=\"#fnref1:2\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:3\">\n<p>ITU-T, <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.651.1-201811-I\/en\" rel=\"nofollow noopener\" target=\"_blank\">G.651.1 (11\/2018) \u2014 Characteristics of a 50\/125 \u00b5m multimode graded index optical fibre cable for the optical access network<\/a>, linked English recommendation, scope and clauses 5\u20137, checked 19 November 2026. Its specific access-network and bandwidth scope is not a complete specification for every multimode category.&#160;<a href=\"#fnref1:3\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:4\">\n<p>IEC, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/79333\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60793-1-40:2024 \u2014 Attenuation measurement methods<\/a>, public summary checked 19 November 2026. The complete paid standard was not accessed; no detailed procedure or acceptance limit is inferred from the summary.&#160;<a href=\"#fnref1:4\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:5\">\n<p>IEC, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/94214\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60793-1-41:2024 \u2014 Bandwidth, current-edition public summary on the RLV listing<\/a>, checked 19 November 2026. The listing identifies the 2024 revision replacing 2010 and the distinction between modal-bandwidth methods. The paid standard and redline were not accessed; the project must select its applicable method and required bandwidth property.&#160;<a href=\"#fnref1:5\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<li id=\"fn:6\">\n<p>EXFO, <a href=\"https:\/\/www.exfo.com\/en\/products\/field-network-testing\/light-sources\/encircled-flux-compliant-light-source\/\" rel=\"nofollow noopener\" target=\"_blank\">Encircled flux compliant light source \u2014 understanding encircled flux<\/a>, checked 19 November 2026. Manufacturer explanation of multimode link-loss launch conditions only; no EXFO instrument performance or service scope is transferred to HONGKAI.&#160;<a href=\"#fnref1:6\" rev=\"footnote\" class=\"footnote-backref\">\u21a9<\/a><\/p>\n<\/li>\n<\/ol>\n<\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>\u0628\u0627 \u062a\u0641\u06a9\u06cc\u06a9 \u0645\u0634\u062e\u0635\u0627\u062a \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc\u060c \u0633\u0627\u062e\u062a\u0627\u0631 \u0641\u06cc\u0632\u06cc\u06a9\u06cc \u06a9\u0627\u0628\u0644\u060c \u0631\u0627\u0628\u0637\u200c\u0647\u0627\u06cc \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0642\u0627\u0628\u0644 \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0645\u062c\u062f\u062f \u0648 \u0634\u0648\u0627\u0647\u062f \u062a\u0633\u062a \u062e\u0627\u0635 \u0645\u062d\u0635\u0648\u0644\u060c \u06cc\u06a9 \u0645\u062d\u062f\u0648\u062f\u0647 \u06a9\u0627\u0628\u0644 \u0627\u0648\u0644\u06cc\u0647 \u0631\u0627 \u0627\u0646\u062a\u062e\u0627\u0628 \u06a9\u0646\u06cc\u062f.<\/p>","protected":false},"author":1,"featured_media":19129,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"page_builder":"","thumbnail_url":"","footnotes":""},"categories":[879,878],"tags":[],"buyer-route":[],"process":[],"class_list":["post-19127","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","category-fiber-optic-cable"],"acf":[],"_links":{"self":[{"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/posts\/19127","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/comments?post=19127"}],"version-history":[{"count":4,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/posts\/19127\/revisions"}],"predecessor-version":[{"id":19137,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/posts\/19127\/revisions\/19137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/media\/19129"}],"wp:attachment":[{"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/media?parent=19127"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/categories?post=19127"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/tags?post=19127"},{"taxonomy":"buyer-route","embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/buyer-route?post=19127"},{"taxonomy":"process","embeddable":true,"href":"https:\/\/hkcablemachine.com\/fa\/wp-json\/wp\/v2\/process?post=19127"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}